Gear oil pump series
High viscosity pump series
Centrifugal pump series
Pump series for other purposes
BRY air-cooled high-temperature centrifugal pump
BRY air-cooled high-temperature centrifugal pump is an energy-saving new product designed and manufactured in accordance with GB5662. The pump has excellent performance, reasonable structure, and is suitable for use. Suitable for conveying high-temperature liquids without solid particles.
Its degree and usage temperature are divided into three categories based on the material of the main parts in contact with the medium, 1. HT200. ZG230-450. 3.1Gr18Ni9Ti. 0Gr18Ni12Mo2Ti.
BRY air-cooled high-temperature centrifugal pump is suitable for the following ranges
1. Petroleum and chemical industry: polymerization, condensation, distillation, distillation, melting, etc;
2. Oil and fat industry: distillation of fatty acids, decomposition of oils and fats, esterification, etc;
3. Synthetic fiber industry: polymerization melting, spinning, extension, etc;
4. Textile printing and dyeing industry: heat setting, drying, hot melt dyeing, etc;
5. Plastic and rubber industry: hot pressing, rolling, extrusion, vulcanization molding, etc;
6. Paper industry: drying, corrugated paper processing, etc;
7. Wood industry: plywood, fiber hot pressing, wood drying, etc;
8. Construction industry: asphalt heating, etc; In addition, it is widely used in the mechanical industry and pharmaceutical production.
Performance range of BRY air-cooled high-temperature centrifugal pump (according to design points)
1. Flow rate 1-500 meters ³/ H; 2. Lift 10-125m; 3. Temperature -20 º C-350 º C;
BRY air-cooled high-temperature centrifugal pump model representation: Taking BRY50-32-200A as an example
BRY 50-32-200 A
BRY means: hot oil pump
50 represents: pump inlet diameter (mm)
32 represents: pump outlet diameter (mm)
200 represents: nominal outer diameter of impeller (mm)
A represents: one-time cutting of impeller outer diameter
Explanation: The order of impeller diameters is represented by A, B, and C. Cutting is not indicated for larger diameters.
Technical parameters of BRY air-cooled high-temperature centrifugal pump
model | Entrance and exit caliber mm | flow | liftM | speed r/min | power | power % | Equipped with motor model | ||
m³/h | L/min | Shaft powerKw | Power allocationKw | ||||||
BRY20-20-125 | 20×20 | 1.5 | 25 | 22 | 2800 | 0.22 | 0.75 | 30 | Y80M |
BRY25-25-160 | 25×25 | 3.0 | 50 | 27 | 2840 | 0.53 | 1.5 | 30 | Y90S |
BRY32-32-160 | 32×32 | 6.0 | 100 | 28 | 2840 | 0.85 | 1.5 | 45 | Y90S |
BRY40-25-160 | 40×25 | 10 | 166 | 28 | 2840 | 1.72 | 2.2 | 50 | Y90L |
BRY50-32-160 | 50×32 | 7.5 | 125 | 34 | 2840 | 1.59 | 3.0 | 44 | Y100L |
12.5 | 208 | 30 | 2.02 | 54 | |||||
15 | 250 | 29 | 2.16 | 56 | |||||
BRY50-32-200 | 50×32 | 7.5 | 125 | 52.5 | 2900 | 2.82 | 5.5 | 38 | Y132S |
12.5 | 208 | 50 | 3.54 | 48 | |||||
18 | 300 | 40 | 3.92 | 51 | |||||
BRY50-32-200A | 50×32 | 16 | 266 | 32 | 2900 | 3.35 | 4.0 | 42 | Y112M |
BRY50-32-250 | 50×32 | 7.5 | 125 | 82 | 2900 | 5.8 | 11 | 28 | Y160M |
12.5 | 208 | 80 | 7.2 | 38 | |||||
18 | 300 | 70 | 7.8 | 51 | |||||
BRY50-32-250A | 50×32 | 16 | 266 | 60 | 2900 | 6.3 | 7.5 | 42 | Y132S |
BRY65-50-160 | 65×50 | 20 | 333 | 32 | 2900 | 3.17 | 5.5 | 55 | Y132S |
25 | 416 | 30 | 3.35 | 65 | |||||
30 | 500 | 27 | 3.71 | 66 | |||||
BRY65-40-200 | 65×40 | 15 | 250 | 48 | 2900 | 4.4 | 7.5 | 49 | Y132S |
25 | 416 | 50 | 5.7 | 60 | |||||
30 | 500 | 48 | 6.3 | 61 | |||||
BRY65-40-200A | 65×40 | 25 | 416 | 35 | 2900 | 4.0 | 5.5 | 59 | Y132S |
BRY65-40-250 | 65×40 | 15 | 250 | 82 | 2900 | 9.1 | 15 | 37 | Y160M |
25 | 416 | 80 | 10.3 | 53 | |||||
30 | 500 | 87 | 12.02 | 54 | |||||
BRY65-40-250A | 65×40 | 20 | 333 | 51 | 2900 | 5.67 | 7.5 | 49 | Y132S |
BRY65-40-315 | 65×40 | 15 | 250 | 127 | 2900 | 18.5 | 30 | 28 | Y200L |
25 | 416 | 125 | 21.3 | 40 | |||||
30 | 500 | 123 | 23 | 44 | |||||
BRY65-40-31 | 65×40 | 22.5 | 375 | 100 | 2900 | 15.3 | 22 | 40 | Y180M |
BRY80-50-200 | 80×50 | 40 | 666 | 52 | 2900 | 7.87 | 15 | 55 | Y160M |
50 | 832 | 50 | 9.8 | 70 | |||||
60 | 1000 | 46 | 10.8 | 71 | |||||
BRY80-50-200A | 80×50 | 45 | 750 | 40 | 2900 | 7.8 | 11 | 63 | Y160M |
BRY80-50-200B | 80×50 | 40 | 666 | 32 | 2900 | 6.37 | 7.5 | 55 | Y132S |
BRY80-50-250 | 80×50 | 30 | 500 | 84 | 2900 | 13.2 | 22 | 52 | Y180M |
50 | 832 | 80 | 17.3 | 63 | |||||
60 | 1000 | 72 | 19.2 | 64 | |||||
BRY80-50-250A | 80×50 | 43 | 716 | 60 | 2900 | 12.8 | 15 | 55 | Y160M |
BRY80-50-315 | 80×50 | 30 | 500 | 128 | 2900 | 25.5 | 37 | 41 | Y200L |
50 | 832 | 125 | 31.5 | 56 | |||||
60 | 1000 | 123 | 35.3 | 58 | |||||
BRY80-50-31 | 80×50 | 45 | 750 | 100 | 2900 | 23.6 | 30 | 52 | Y200L |
BRY100-65-200 | 100×65 | 60 | 1000 | 54 | 2900 | 13.6 | 22 | 65 | Y180M |
100 | 1664 | 50 | 17.9 | 76 | |||||
120 | 2000 | 47 | 19.9 | 77 | |||||
BRY100-65-200A | 100×65 | 94 | 1566 | 44 | 2900 | 16 | 22 | 70 | Y180M |
BRY100-65-200B | 100×65 | 87 | 1450 | 38 | 2900 | 13.8 | 15 | 65 | Y160M |
BRY100-65-200C | 100×65 | 80 | 1333 | 32 | 2900 | 11.8 | 15 | 59 | Y160M |
BRY100-65-250 | 100×65 | 60 | 1000 | 87 | 2900 | 23.4 | 37 | 60 | Y200L |
100 | 1664 | 80 | 30.3 | 73 | |||||
120 | 2000 | 74 | 33.3 | 74 | |||||
BRY100-65-250A | 100×65 | 95 | 1583 | 72 | 2900 | 29 | 37 | 64 | Y200L |
BRY100-65-250B | 100×65 | 90 | 1500 | 65 | 2900 | 26.2 | 30 | 61 | Y200L |
BRY100-65-250C | 100×65 | 85 | 1416 | 50 | 2900 | 20.3 | 30 | 57 | Y200L |
BRY100-65-315 | 100×65 | 60 | 1000 | 133 | 2900 | 39.6 | 75 | 55 | Y280S |
100 | 1664 | 125 | 51.6 | 66 | |||||
120 | 2000 | 118 | 57.5 | 67 | |||||
BRY100-65-31 | 100×65 | 95 | 1583 | 113 | 2900 | 45.2 | 55 | 64 | Y250M |
BRY100-65-315B | 100×65 | 90 | 1500 | 100 | 2900 | 40.5 | 55 | 55 | Y250M |
BRY100-65-315C | 100×65 | 82 | 1366 | 84 | 2900 | 34.8 | 45 | 54 | Y225M |
BRY125-100-200 | 125×100 | 120 | 2000 | 57.5 | 2900 | 39.6 | 45 | 67 | Y225M |
200 | 3328 | 50 | 51.6 | 81 | |||||
240 | 4000 | 44.5 | 57.5 | 80 | |||||
BRY125-100-200A | 125×100 | 178 | 2966 | 40 | 2900 | 26.6 | 37 | 73 | Y200L |
BRY125-100-250 | 125×100 | 160 | 2666 | 76 | 2900 | 44.2 | 55 | 75 | Y250M |
200 | 3328 | 70 | 47 | 80 | |||||
240 | 4000 | 60 | 50.3 | 78 |
Advantages and disadvantages of high viscosity pumps and gear pumps compared to each other
Comparative analysis of advantages and disadvantages between high viscosity pumps and gear ...
2025-01-17
Research Report on the Characteristics and Applications of High Viscosity Pumps
1、 Research background As a key equipment used in the industrial field to transport high ...
2025-01-13
Research Report on the Differences between Clean Water Pump and Gear Oil Pump
1、 Research background In industrial production and daily life, water pumps are an extrem ...
2025-01-08
Application of Thermal Transfer Oil Pump in Boiler Circulation System
In the fields of modern industrial production and energy supply, boilers, as an important t ...
2025-01-06